Ceiling Air Handling Unit
A compact, low-profile duct-mounted air handling unit ideal for modern commercial offices, hotels, and healthcare buildings with limited ceiling space. Constructed with low-vibration centrifugal fans and heavy-duty cooling coils, it provides exceptional indoor air quality, whisper-quiet operation, and easy maintenance access.
Airflow, fan quantity and noise
| Model |
Airflow (m³/h) |
Fan sets |
Noise dB(A) |
| HCGD010B |
1000 |
1 |
58 |
| HCGD020B |
2000 |
1 |
59 |
| HCGD025B |
2500 |
1 |
59 |
| HCGD030B |
3000 |
1 |
60 |
| HCGD040B |
4000 |
2 |
61 |
| HCGD050B |
5000 |
2 |
62 |
| HCGD060B |
6000 |
2 |
63 |
| HCGD080B |
8000 |
2 |
64 |
| HCGD100B |
10000 |
2 |
68 |
| HCGD125B |
12500 |
2 |
69 |
| HCGD150B |
15000 |
2 |
73 |
External static pressure and fan power
| Model |
4-row ESP (Pa) |
6-row ESP (Pa) |
8-row ESP (Pa) |
Fan power (kW) |
| HCGD010B |
200 |
150 |
100 |
0.32 |
| HCGD020B |
200 |
150 |
100 |
0.37 |
| HCGD025B |
250 |
200 |
150 |
0.45 |
| HCGD030B |
250 |
200 |
150 |
0.55 |
| HCGD040B |
250 |
200 |
150 |
0.45 × 2 |
| HCGD050B |
300 |
250 |
200 |
0.55 × 2 |
| HCGD060B |
300 |
250 |
200 |
0.55 × 2 |
| HCGD080B |
300 |
250 |
200 |
1.1 × 2 |
| HCGD100B |
350 |
300 |
250 |
1.3 × 2 |
| HCGD125B |
350 |
300 |
250 |
1.8 × 2 |
| HCGD150B |
400 |
350 |
300 |
2.2 × 2 |
Unit weight
| Model |
4-row coil (kg) |
6-row coil (kg) |
8-row coil (kg) |
| HCGD010B |
66 |
69 |
72 |
| HCGD020B |
77 |
81 |
85 |
| HCGD025B |
80 |
84 |
89 |
| HCGD030B |
92 |
98 |
103 |
| HCGD040B |
116 |
124 |
131 |
| HCGD050B |
129 |
138 |
147 |
| HCGD060B |
142 |
153 |
164 |
| HCGD080B |
169 |
183 |
196 |
| HCGD100B |
225 |
241 |
257 |
| HCGD125B |
249 |
267 |
286 |
| HCGD150B |
295 |
317 |
338 |
Return-air cooling, 6-row coil
| Model |
Capacity (kW) |
Water flow (m³/h) |
Water resistance (kPa) |
| HCGD010B |
8.5 |
1.62 |
10.1 |
| HCGD020B |
15.2 |
2.88 |
11.9 |
| HCGD025B |
18.9 |
3.58 |
12.5 |
| HCGD030B |
22.8 |
4.32 |
12.8 |
| HCGD040B |
30.2 |
5.72 |
13.5 |
| HCGD050B |
37.7 |
7.14 |
13.6 |
| HCGD060B |
45.3 |
8.57 |
16.6 |
| HCGD080B |
66.4 |
12.57 |
16.7 |
| HCGD100B |
78.7 |
14.89 |
17.8 |
| HCGD125B |
91.7 |
17.36 |
17.5 |
| HCGD150B |
110 |
20.81 |
18.5 |
Return-air heating, 6-row coil
| Model |
Capacity (kW) |
Water flow (m³/h) |
Water resistance (kPa) |
| HCGD010B |
15.3 |
2.89 |
8.3 |
| HCGD020B |
25.3 |
4.79 |
11.9 |
| HCGD025B |
31.5 |
5.96 |
12.5 |
| HCGD030B |
38.5 |
7.29 |
12.8 |
| HCGD040B |
51.8 |
9.8 |
13.5 |
| HCGD050B |
62.4 |
11.81 |
13.6 |
| HCGD060B |
75.4 |
14.27 |
16.6 |
| HCGD080B |
96.1 |
18.18 |
16.7 |
| HCGD100B |
110.6 |
20.93 |
17.8 |
| HCGD125B |
151.5 |
28.67 |
17.5 |
| HCGD150B |
181.7 |
34.38 |
18.5 |
Fresh-air cooling, 6-row coil
| Model |
Capacity (kW) |
Water flow (m³/h) |
Water resistance (kPa) |
| HCGD010B |
18.3 |
3.35 |
15.5 |
| HCGD020B |
31.2 |
5.72 |
21.42 |
| HCGD025B |
38.8 |
7.11 |
22.5 |
| HCGD030B |
46.1 |
8.45 |
23.04 |
| HCGD040B |
63.7 |
11.67 |
24.3 |
| HCGD050B |
77.3 |
14.16 |
24.48 |
| HCGD060B |
93.6 |
17.15 |
29.88 |
| HCGD080B |
121.3 |
22.22 |
30.06 |
| HCGD100B |
153.3 |
28.08 |
32.04 |
| HCGD125B |
193.7 |
35.49 |
31.56 |
| HCGD150B |
240.3 |
44.02 |
33.3 |
Fresh-air heating, 6-row coil
| Model |
Capacity (kW) |
Water flow (m³/h) |
Water resistance (kPa) |
| HCGD010B |
17.5 |
3.31 |
14.91 |
| HCGD020B |
29.5 |
5.59 |
21.42 |
| HCGD025B |
36.9 |
6.99 |
22.5 |
| HCGD030B |
45.1 |
8.54 |
23.04 |
| HCGD040B |
60.3 |
11.41 |
24.3 |
| HCGD050B |
70.2 |
13.28 |
24.48 |
| HCGD060B |
88.2 |
16.69 |
29.88 |
| HCGD080B |
116 |
21.95 |
30.06 |
| HCGD100B |
142.3 |
26.92 |
32.04 |
| HCGD125B |
177.7 |
33.62 |
30.96 |
| HCGD150B |
212.6 |
40.22 |
33.3 |
Fan construction
| Item |
Specification |
| Fan |
Outer-rotor direct-drive centrifugal fan |
Rating conditions
- Return-air cooling: entering air DB 27°C / WB 19.5°C. Fresh-air cooling: DB 35°C / WB 27.5°C. Chilled water inlet 7°C, water temperature difference 5°C.
- Return-air heating: entering air DB 15°C. Fresh-air heating: entering air DB 7°C. Heating water inlet 60°C.
- Coil performance tables above show the six-row configuration. Four-row and eight-row coils have separate ratings; select the required coil for the project.
Technical data: Haichuang catalogue, printed pages 22-24. B and S identify cabinet and jet-flow versions respectively.