Air Source Heat Pump
A highly versatile air-to-water heat pump featuring energy-efficient DC inverter technology, low-noise axial fans, and heavy-duty anti-corrosion cabinet design. Delivering efficient cooling, heating, and year-round hot water, this unit is ideal for residential villas, hotels, offices, and commercial buildings seeking low operating costs and reduced carbon emissions.
Low-ambient inverter air-source heat pump series. The two cabinet ranges below have separate model codes, sizes and ratings. Heating figures list capacity / power input under the stated condition.
Moulded sheet-metal series, model and electrical data
| Model |
Category / power supply |
Dimensions and weight |
| DPKFXDN-011CI-S |
3P Single Phase 220V 1N~50Hz |
950*400*775 mm 80 kg |
| DPKFXDN-015CI-S |
5P Single Phase 220V 1N~50Hz |
950*400*1430 mm 110 kg |
| DPKFXDN-018CI-S |
6P Single Phase 220V 1N~50Hz |
950*400*1430 mm 110 kg |
| DPKFXDN-018CII-S |
6P Three Phase 380V 3N~50Hz |
950*400*1430 mm 110 kg |
| DPKFXDN-022CII-S |
Small 8P Three Phase 380V 3N~50Hz |
950*400*1430 mm 120 kg |
Moulded sheet-metal series, heating Nominal
| Model |
Heating capacity / input power |
| DPKFXDN-011CI-S |
6.50kW / 2.62kW |
| DPKFXDN-015CI-S |
10.50kW / 4.23kW |
| DPKFXDN-018CI-S |
12.50kW / 5.08kW |
| DPKFXDN-018CII-S |
12.50kW / 5.08kW |
| DPKFXDN-022CII-S |
14.30kW / 5.56kW |
Moulded sheet-metal series, heating A7W45
| Model |
Heating capacity / input power |
| DPKFXDN-011CI-S |
9.0kW / 2.50kW |
| DPKFXDN-015CI-S |
15.0kW / 4.17kW |
| DPKFXDN-018CI-S |
17.0kW / 4.78kW |
| DPKFXDN-018CII-S |
17.0kW / 4.78kW |
| DPKFXDN-022CII-S |
22.10kW / 6.10kW |
Moulded sheet-metal series, heating Low Temp
| Model |
Heating capacity / input power |
| DPKFXDN-011CI-S |
5.50kW / 2.64kW |
| DPKFXDN-015CI-S |
9.50kW / 4.57kW |
| DPKFXDN-018CI-S |
10.20kW / 4.95kW |
| DPKFXDN-018CII-S |
10.20kW / 4.86kW |
| DPKFXDN-022CII-S |
12.80kW / 6.10kW |
Moulded sheet-metal series, refrigerant and compressor
| Model |
Refrigerant / charge and water flow |
Compressor |
| DPKFXDN-011CI-S |
R410A / 2.0kg 1.20 m³/h |
GMCC EVI DC Inverter (EAPM240) |
| DPKFXDN-015CI-S |
R410A / 3.2kg 1.90 m³/h |
GMCC EVI DC Inverter (EAPF310) |
| DPKFXDN-018CI-S |
R410A / 3.2kg 2.30 m³/h |
GMCC EVI DC Inverter (EAPF420) |
| DPKFXDN-018CII-S |
R410A / 3.2kg 2.30 m³/h |
GMCC EVI DC Inverter (EAPF420) |
| DPKFXDN-022CII-S |
R410A / 3.5kg 2.40 m³/h |
GMCC EVI DC Inverter (EAPF420) |
CNC sheet-metal series, model and electrical data
| Model |
Category / power supply |
Dimensions and weight |
| DPKFXDN-015CI-G |
5P Single Phase 220V 1N~50Hz |
1040*470*1396 mm 125 kg |
| DPKFXDN-018CI-G |
6P Single Phase 220V 1N~50Hz |
1040*470*1396 mm 125 kg |
| DPKFXDN-018CII-G |
6P Three Phase 380V 3N~50Hz |
1040*470*1396 mm 125 kg |
| DPKFXDN-022CII-G |
Small 8P Three Phase 380V 3N~50Hz |
1040*470*1396 mm 125 kg |
| DPKFXDN-024CII-G |
8P (Standard) Three Phase 380V 3N~50Hz |
1080*470*1478 mm 165 kg |
| DPKFXDN-028CII-G |
Small 10P Three Phase 380V 3N~50Hz |
1080*470*1478 mm 165 kg |
| DPKFXDN-030CII-G |
10P (Standard) Three Phase 380V 3N~50Hz |
1194*487*1605 mm 226 kg |
| DPKFXDN-032CII-G |
12P Three Phase 380V 3N~50Hz |
1194*487*1605 mm 228 kg |
| DPKFXDN-036CII-G |
15P Three Phase 380V 3N~50Hz |
1194*487*1605 mm 238 kg |
CNC sheet-metal series, heating Nominal
| Model |
Heating capacity / input power |
| DPKFXDN-015CI-G |
10.50kW / 4.05kW |
| DPKFXDN-018CI-G |
11.80kW / 4.57kW |
| DPKFXDN-018CII-G |
11.80kW / 4.57kW |
| DPKFXDN-022CII-G |
14.30kW / 5.56kW |
| DPKFXDN-024CII-G |
16.50kW / 6.40kW |
| DPKFXDN-028CII-G |
17.50kW / 6.85kW |
| DPKFXDN-030CII-G |
20.50kW / 7.85kW |
| DPKFXDN-032CII-G |
22.80kW / 9.20kW |
| DPKFXDN-036CII-G |
27.00kW / 10.54kW |
CNC sheet-metal series, heating A7W45
| Model |
Heating capacity / input power |
| DPKFXDN-015CI-G |
15.02kW / 4.15kW |
| DPKFXDN-018CI-G |
17.21kW / 4.78kW |
| DPKFXDN-018CII-G |
17.21kW / 4.78kW |
| DPKFXDN-022CII-G |
22.10kW / 6.10kW |
| DPKFXDN-024CII-G |
22.50kW / 6.20kW |
| DPKFXDN-028CII-G |
25.50kW / 6.90kW |
| DPKFXDN-030CII-G |
29.50kW / 7.90kW |
| DPKFXDN-032CII-G |
33.00kW / 8.95kW |
| DPKFXDN-036CII-G |
35.80kW / 9.29kW |
CNC sheet-metal series, heating Low Temp
| Model |
Heating capacity / input power |
| DPKFXDN-015CI-G |
9.50kW / 4.52kW |
| DPKFXDN-018CI-G |
10.20kW / 4.86kW |
| DPKFXDN-018CII-G |
10.20kW / 4.86kW |
| DPKFXDN-022CII-G |
12.80kW / 6.10kW |
| DPKFXDN-024CII-G |
14.50kW / 6.90kW |
| DPKFXDN-028CII-G |
15.40kW / 7.40kW |
| DPKFXDN-030CII-G |
17.40kW / 8.30kW |
| DPKFXDN-032CII-G |
19.50kW / 9.35kW |
| DPKFXDN-036CII-G |
23.22 kW / 11.0 kW |
CNC sheet-metal series, cooling and refrigerant
| Model |
Nominal cooling capacity / input power |
Refrigerant / charge and water flow |
| DPKFXDN-015CI-G |
11.5kW / 4.1kW |
R410A / 3.5kg 1.90 m³/h |
| DPKFXDN-018CI-G |
12.5kW / 4.5kW |
R410A / 3.5kg 2.30 m³/h |
| DPKFXDN-018CII-G |
12.5kW / 4.5kW |
R410A / 3.5kg 2.30 m³/h |
| DPKFXDN-022CII-G |
14.5kW / 5.3kW |
R410A / 3.5kg 2.70 m³/h |
| DPKFXDN-024CII-G |
19.5kW / 6.6kW |
R410A / 4.5kg 3.40 m³/h |
| DPKFXDN-028CII-G |
21.5kW / 7.3kW |
R410A / 4.5kg 3.60 m³/h |
| DPKFXDN-030CII-G |
23.5kW / 7.65kW |
R410A / 6.0kg 3.90 m³/h |
| DPKFXDN-032CII-G |
24.5kW / 9.0kW |
R410A / 6.8kg 4.50 m³/h |
| DPKFXDN-036CII-G |
29.3kW / 10.65kW |
R410A / 6.8kg 4.65 m³/h |
Rating conditions
- A7W45 normal-temperature heating: ambient dry-bulb 7°C, wet-bulb 6°C, water inlet/outlet 40°C / 45°C.
- Nominal heating: ambient dry-bulb -12°C, wet-bulb -13.5°C, outlet water 41°C.
- Low-temperature nominal heating: ambient dry-bulb -20°C, outlet water 41°C.
- Recommended floor areas depend on building heat loss, climate and terminal selection. No universal coverage area is promised; confirm the project load before selection.
Technical data: Haichuang data sheet 6.
Gallery images include different cabinet configurations from the supplied product series. Photographic backgrounds have been prepared for presentation; confirm the selected model and final appearance before ordering.